Windmill Cables
EPR/HFXLEVA LSOH 0.6/1kV Torsion Resistant Power Cable HFEPR/HFEVA 0.6/1kV LSOH Screened Torsion Resistant Power Cable Al Conductor EPR/XLEVA 0.6/1kV LSOH Power Cable 90℃ more

  Windmill Cables

PUR Sheathed, Screened, Halogen Free Data Cable

Application

These halogen free cables are used as drag chain cables for frequent and fast lifting and bending stresses in

machines and tool building, robot systems and constantly moving machine components.

Standards

UL AWM Style 20233

CSA AWM I/II A/B

Construction

Windmill Cables

Conductor: Stranded bare copper, class 6 according to VDE 0295/BS 6360.

Insulation: Polyolefin.

Screen: Tinned copper wire braid.

Sheath: Full polyurethane sheath TMPU.

Technical Data

Rated Voltage Uo/U (Um):300V

Operating Temperatures:flexing: -40℃~+80℃; fixed: -50℃~+80℃

Minimum Bending Radius:flexing: 7.5×OD; fixed: 4×OD

Flame Retardant:VDE 0482-332-1-2/DIN EN 60332-1-2/IEC 60332-1

Oil Resistant:Yes

Halogen Free:Yes

Ozone, Oxygen Resistant:Yes

Silicone Free:Yes

UV Resistant:Yes

Abrasion Resistance:Yes

Dimensions and Weight

Construction Nominal Overall Diameter Nominal Weight
No. of cores×mm² mm kg/km
26AWG
2×0.14 4.3 32
3×0.14 4.6 35
4×0.14 4.8 40
5×0.14 5.1 45
7×0.14 5.8 66
10×0.14 6.8 86
12×0.14 7.4 94
14×0.14 7.4 102
18×0.14 7.8 118
24×0.14 8.8 149
25×0.14 9.2 156
24AWG
2×0.25 5.0 38
3×0.25 5.2 44
4×0.25 5.6 51
5×0.25 5.9 68
7×0.25 6.8 82
10×0.25 8.3 110
12×0.25 8.4 124
14×0.25 8.9 135
18×0.25 9.5 150
24×0.25 10.8 194
25×0.25 11.3 204
22AWG
2×0.34 5.4 45
3×0.34 5.7 60
4×0.34 6.0 76
5×0.34 6.5 82
7×0.34 7.7 110
10×0.34 9.1 148
12×0.34 10.0 166
14×0.34 10.0 185
18×0.34 10.6 216
24×0.34 12.1 291
25×0.34 12.8 305